Non-Destructive Evaluation of Concrete Strength for Rehabilitation

Scope FPrimeC Solutions Inc. was engaged by the client to estimate the in-place concrete strength for various structural members in York University through a non-destructive testing and evaluationg program. The main objective was to provide realistic estimate of concrete strength for upgrading and rehabilitation of various structural

Read More

In-Place Estimate of Concrete Strength

  Scope FPrimeC was engaged by Aecon to estimate the in-place concrete strength for a massive concrete structure in a gold mine construction in Northern Ontario. Due to complex reinforcement configuration, the concrete was not consolidated properly. The complex geometry of the silo bin, and embedded steel plates was another challenge